Journal of the Korean Academy of Pediatric Dentistry 2001;28(4):638-642.
Published online November 30, 2001.
A STUDY ON THE SHEAR BOND STRENGTH BY PLASMA ARC CURING SYSTEM FOR BRACKET BONDING
 
Plasma arc curing system을 이용한 브라켓의 접착에 관한 연구
김정윤, 김종수, 권순원
단국대학교 치과대학 소아치과학 교실
Abstract
Recently, plasma arc curing system for curing resin composites has been introduced. This is characterized by a high output of light energy, which has the advantage of reducing the chair time and thereby making the treatment more comportable for the patients as well as for the dentist. The purpose of this study was to compare the shear bond strengths of light-cured orthodontic adhesive polymerized with conventional halogen light and plasma arc light. The 2 curing devices used were the XL3000 (3M, USA) conventional curing light and the Flipo (LOKKI, France) plasma arc light. The results from the present study can be summarized as fellows; 1. The mean shear bond strength for three groups were quite similar for 50 second conventional light group, 2 second plasma arc curing light group, 5 second plasma arc curing light group. 2. There was no statistically significant difference for three groups(p>0.05).
Key Words: Plasma arc light, Halogen light, Light curing, Shear bond strength